Flammability UL 94 HBF

Horizontal Burning Foamed Material

The horizontal burning test on foamed materials is used to determine the UL 94-HBF, HF-1 and HF-2 flammability ratings taking account of the calculated density.

Vorbehandlung:
2 days / 23 °C / 50 % relative humidity.
7 days / 70 °C / hot air oven

Flame height 38 mm
Flame application time 60 s

 

Flammability rating UL 94 HBF
Test criteria (test specimens) HF-1 HF-2
Burning time (s) 4/5 ≤ 2
1/5 ≤ 10
4/5 ≤ 2
1/5 ≤ 10
Burning and afterglow times of each individual specimen (s) ≤ 30 ≤ 30
Dripping of burning specimens
(ignition of cotton batting)
no yes
Damaged length of each individual specimen (mm) < 60 < 60
Criteria for HBF ratings
  • Burning rate ≤ 40mm over a distance of 100 mm
  • Flame or glow is extinguished before 125 mm mark
NOTICE: DUE TO GDPR, OUR EMAIL POLICIES ARE CHANGING FOR THE EUROPEAN UNION
UL is transitioning to a new email policy as part of our commitment to your digital security and privacy. Please confirm your wish to continue to receive periodic emails from UL containing best practices, education, industry research, news, updates and promotions related to UL‘s products and services by clicking CONFIRM