Flammability UL 94 V

50 W, 20 mm Vertical

This method is used to determine the UL 94 V-0, V-1 and V-2 flammability ratings.

The test evaluates both the burning and afterglow times and dripping of the burning test specimen.

Pre-treatment:
2 days / 23 °C / 50 % relative humidity
7 days / 70 °C / hot air oven

Flame height 20 mm
Flame application time 2 x 10 s
The second flame application time begins as soon as the first burning time ends

 

Flammability rating UL 94 V
Test criteria V-0 V-1 V-2
Burning time of each individual test specimen (s)
(after first and second flame applications)
≤10 ≤30 ≤30
Total burning time (s)
(10 flame applications)
≤50 ≤250 ≤250
Burning and afterglow times after second flame application (s) ≤30 ≤60 ≤60
Dripping of burning specimens
(ignition of cotton batting)
no no yes
Combustion up to holding clamp
(specimens completely burned)
no no no
NOTICE: DUE TO GDPR, OUR EMAIL POLICIES ARE CHANGING FOR THE EUROPEAN UNION
UL is transitioning to a new email policy as part of our commitment to your digital security and privacy. Please confirm your wish to continue to receive periodic emails from UL containing best practices, education, industry research, news, updates and promotions related to UL‘s products and services by clicking CONFIRM