Flammability UL 94 HB

Horziontal Burning

The horizontal burning test is used to determine the HB flammability rating of a material.

The flammability rating is calculated for a test specimen as a function of the burning rate and taking account of the material thickness.

Pre-treatment:
48 hours / 23°C / relative humidity

Flame application 20 mm high Tirill burner flame
Flame application time 30 s
If the flame front reaches the first mark within 30 s, flame application is discontinued. 

 

Test criteria Burning rate in V Flammability rating
Test specimen thickness 3 - 13 mm ≤ 40 mm/min HB
Test specimen thickness ‹ 3 mm ≤ 75 mm/min HB
Flame is extinguished before first mark = 0 mm/min HB
NOTICE: DUE TO GDPR, OUR EMAIL POLICIES ARE CHANGING FOR THE EUROPEAN UNION
UL is transitioning to a new email policy as part of our commitment to your digital security and privacy. Please confirm your wish to continue to receive periodic emails from UL containing best practices, education, industry research, news, updates and promotions related to UL‘s products and services by clicking CONFIRM